Professional benchtop multiparameter meter with an innovative high-definition backlit color LCD display, with adjustable brightness.
Management of DHS digital sensors.
Select the parameters you want to display.
Online setup and calibration guidance allows for simple and immediate use of the device.
Automatic pH calibration with USA and NIST buffers for up to 3 points and 2 user-defined points.
Automatic ORP calibration for 1 point.
Calibrated values are indicated with icons.
Automatic conductivity calibration for up to 5 points (84, 147, 1413 μS and 12.88, 111.8 mS) and one user-defined point.
Automatic scale change, selectable reference temperature (15…30°C), and selectable cell constant (C = 0.1, 1, 10).
Measurement stability indicator and 3 selectable stability levels.
All operations are constantly monitored and reported to the operator via the colored LED above the display and self-diagnostic messages.
Plus...
- GLP functions: Date and time, calibration data display, and calibration expiration date.
- Data logger for up to 1,000 data points, manual and automatic, with the option of downloading data to a PC via micro-USB.
- Data-Link software
- Connection to an external printer via RS232 connector.
| Technical specifications |
PC 60 VioLab |
| pH Measuring Range |
-2,00… 16,00 |
| Resolution / Accuracy |
0.1, 0.01 / +0.02 |
| Calibration points |
1...3 auto values - 2 user values |
| Recognized buffers |
USA, NIST, 2 valori user |
| DHS sensor recognition |
Yes |
| mV Measurement range |
-1000 … +1900 |
| Resolution: |
0.1 / 1 |
| ORP Calibration Points |
1 point = 475 mV |
| COND Measuring Range |
0,00 ... 200 mS |
| Resolution |
0,01 - 0,1 - 1 µS / mS (scala automatica) |
| Accuracy |
± 2% f.s. |
| Calibration points |
1...5 |
| Recognized buffers |
1...5 µS - 84 µS - 147 µS -1413 µS - 12,88 mS - 111,8 mS + 1 User |
| Reference temperature |
15 ... 30 °C |
| Temperature coefficient |
0,00 ... 10.00 % / °C |
| Buffer Indication |
Yes |
| TDS Measurement Range |
0.1 mg/l ... 200 g/l |
| TDS Factor |
0.40 ... 1.00 |
| Salinity Measuring range |
0.1 ppm ... 100 ppt |
| Temperature Measuring range |
-10,0… 110.0 °C |
| Resolution / Accuracy |
0.1 / ± 0.5°C |
| Temperature compensation |
0,0… 100.0 °C |
| System : LPG |
Yes |
| Calibration timer |
Yes |
| Buffer Indication |
Yes |
| Calibration Report |
Yes, printable |
| Stability criteria |
Low – Nor - High |
| Internal memory |
1000 Data |
| Display |
High-definition color LCD |
| Brightness management |
Manual |
| IP rating |
IP 54 |
| Output |
Micro USB e RS 232 |
| Power supply |
5 V adapter |
| Electrical voltage |
100 … 240 V |
| Operating Conditions |
0 to +45 °C |
| Size / Weight |