Code HI98191

Portable pH-meter mod. HI 98191

waterproof portable pH / ORP / ISE meter

For pH measurements, the HI98191 is supplied complete with the HI72911B titanium body pH electrode, with built-in temperature sensor for automatic temperature compensation measurements.
The titanium probe body is resistant to harsh chemicals and virtually indestructible.

The Hanna CAL Check ™ feature alerts the user if any problems are detected during calibration. By comparing the previous calibration data with the current calibration, the instrument will alert the user with messages on the display if the probe is dirty or broken, or if the pH standard solution is contaminated. After calibration, the general condition of the probe is shown on the display as a percentage from 0 to 100% in 10% increments. The condition of the probe is affected by the offset and slope values of the pH electrode and is displayed in the measurement screen on the calibration day and in the GLP data. Calibration can be performed up to five points with seven stored standard solutions and five customizable, to achieve a pH accuracy of ± 0.002 with a pH resolution of ± 0.001.

HI98191 has 15 different ISE sensors stored inside the meter.
By selecting the appropriate ISE sensor in the ISE Setup menu, the ion charge and molar weight of the ion are applied to display the ISE slope percentage. The user can calibrate the instrument up to five points by choosing from six standard values. This tool allows you to select the unit of measurement from a wide choice (ppm, ppt, g / L, ppb, μg / L, mg / mL, M, mol / L, mmol / L,% w / v, defined by 'user) with a wide measurement range from 1.00 x 10 -7 to 9.99 x 10 10 .
By pressing the “AutoHold” key in measurement mode, the instrument will freeze the measured value on the display, allowing the user to record it. The “out of calibration range” warning can be activated to alert the user that the measurement is out of the pH calibration range.
The logging mode allows the user to store and save up to 300 samples (100 for each parameter: pH, mV and ISE). Values recorded along with associated GLP information can later be transferred to PC with Hanna HI920015 micro USB cable and HI92000 software.
The online help can be accessed at any time by pressing the appropriate button to view specific information on the current screen.

The high contrast of the display ensures excellent viewing outdoors, both in sunlight and in poorly lit areas using the backlight. It is also possible to choose the interface language.

The hard case contains all the components necessary to perform a measurement in the field: instrument, electrode, beaker, calibration, cleaning and storage solutions.


MAIN APPLICATIONS:
Food and Beverage, Plating, Water, Waste Water, Chemical Industry, Agriculture, Environment


HI98191 is supplied complete with:
pH electrode with titanium body HI72911B,
HI7004M pH 4.01 calibration solution (230 mL),
pH 7.01 calibration solution HI7007M (230 mL),
cleaning solution in HI700601 sachet (2 x 20 mL),
100 mL plastic beaker (2),
1.5V AA batteries (4),
HI92000 PC software,
HI920015 micro USB cable,
instruction manual,
quick reference guide,
instrument quality certificate
hard case HI720191.


PH scale

from -2.0 to 20.0 pH; from -2.00 to 20.00 pH; from -2,000 to 20,000 pH

PH resolution

0.1 pH; 0.01 pH; 0.001 pH

PH accuracy

± 0.1; ± 0.002 pH

PH calibration

up to five points, seven standard solutions available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five customizable

Input impedance pH

10¹² Ohms

MV scale

± 2000 mV

MV resolution

0.1 mV

MV accuracy

± 0.2 mV

ISE scale

from 1.00 E⁻⁷ to 9.99 E¹⁰

ISE Resolution

3 significant digits 0.01; 0.1; 1; 10

ISE accuracy

± 0.5% of reading (monovalent ions), ± 1% of reading (divalent ions)

ISE calibration

up to five points, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)

Temperature scale

-20.0 to 120.0 ° C (-4.0 to 248.0 ° F)

Resolution Temperature

0.1 ° C (0.1 ° F)

Accuracy Temperature

± 0.4 ° C (± 0.8 ° F) (excluding probe error)

Temperature Compensation

manual or automatic -20.0 to 120.0 ° C (-4.0 to 248.0 ° F)

PH electrode

HI72911B titanium body pH electrode, internal temperature sensor, BNC connector and 1 m (3.3 ') cable

Registration Type

Manual

Registration Memory

300 samples (100 for each parameter: pH, mV and ISE)

Connection

opto-isolated USB input with optional HI92000 software and micro USB cable

Automatic Power Off

user selectable: 5, 10, 30, 60 min or disabled

Battery Type / Duration

1.5V AA batteries (4) / approx.200 hours of continuous use without backlight (50 hours with backlight)

Terms of Use

0 to 50 ° C (32 to 122 ° F); RH max 100% (IP67)

Dimensions

185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 ")

Weight

400 g (14.2 oz.)

Accessories

Code HI72911B
HI 72911B titanium pH electrode

CONTACTS


ENRICO BRUNO s.r.l.
Via Duino 140
10127 Torino Italy
Tel. +39 011 3160808
Fax +39 011 3160753
PEC pec@pec.enrico-bruno.it
CF/P.IVA: 04891320014

WRITE TO US


For orders, prices requests and offers, technical service commerciale@enrico-bruno.it
For administration service amministrazione@enrico-bruno.it
For Direction – Purchase Department acquisti@enrico-bruno.it

FOLLOW US


Facebook Twitter Blogger